印度肥婆丰满bbw,娇乳欲女h奶汁翘,漂亮人妻办公室里沦陷,日韩Aⅴ人妻无码一区二区

產(chǎn)品詳情
  • 產(chǎn)品名稱:Mouse SCCA2 (Squamous Cell Carcinoma Antigen 2) CLIA Kit (STJC0001435)

  • 產(chǎn)品型號:STJC0001435
  • 產(chǎn)品廠商:ST john's laboratory
  • 產(chǎn)品文檔:
你添加了1件商品 查看購物車
簡單介紹:
Mouse SCCA2 (Squamous Cell Carcinoma Antigen 2) CLIA Kit (STJC0001435)
詳情介紹:
Applications: CLIA
Reactivity: Mouse
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This mouse SCCA2 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Specificity: This kit recognizes Mouse SCCA2 in samples. No significant cross-reactivity or interference between Mouse SCCA2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Specificity This kit recognizes Mouse SCCA2 in samples. No significant cross-reactivity or interference between Mouse SCCA2 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 91-106 97
EDTA plasma(n=8) 84-98 90
Cell culture media(n=8) 92-106 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 41.66 112.02 281.13 40.66 117.69 268.23
Standard deviation 3.51 11.43 29.57 4.92 13.99 23.77
CV (%) 8.43 10.20 10.52 12.10 11.89 8.86